Elata E400 Hybrid Mattress System
One mattress, two levels of care. The E400 is a hybrid mattress designed for adaptable pressure care. Used alone, it offers static foam and air support to help prevent and treat Stage 2 injuries. With the addition of the pump EP10AU, it transitions seamlessly into dynamic alternating therapy, delivering effective treatment up to Stage 4.
Adaptable, dependable, and built for evolving care—step up or step down with confidence.
Why Clinicians Choose E400
E400 is chosen for its flexibility. It works as a comfortable hybrid mattress on its own, then steps up to dynamic therapy when paired with a pump. That adaptability makes it ideal for changing clinical needs, remote care, and environments where power access is not always guaranteed. Clinicians trust E400 because it supports both progression and recovery, without forcing an early commitment to powered therapy.
Combines foam and air cell technology for versatile pressure care across varying risk levels.
Core Foam
Five pairs of transverse air cells with foam inserts, encased in a waterproof TPU cover which reduce noise and block fluid ingress.
Side Wall Support
Adds stability and edge awareness for safer transfers enhancing comfort, balance and confidence.
Stability Core Layer
Supportive base layer enhancing stability, comfort, and pressure relief.
Cable Tidy
Integrated channels secure cables for safer bedside setups and protect against wire damage.
Accessible Handles
To ensure easy control / transport.
Heel Slope
Gentle decline at the foot end reduces heel pressure and helps prevent injuries.
Rebound Core Foam
High rebound foam improves airflow and redistributes pressure. Anti-shear top layer moves with the user to protect skin.
Heel Offloading foldable foam suspends the heels to relieve pressure and prevent injuries.
Pure Guard Cover, Hydro Lock Barrier
Easy to clean, 4-way stretch, vapour-permeable cover that reduces shear and blocks fluids, bacteria, and viruses.
Hydro Lock barrier, a welded seam and liquid-resistant zip flap prevent fluid penetration, protecting mattress integrity.
Why It Matters
Care needs are not static. E400 allows clinicians to respond as conditions change, delivering comfort in static use and active pressure redistribution when therapy is required. It reduces unnecessary mattress changes, simplifies workflows, and supports continuity of care across settings. The result is smoother transitions, better comfort, and pressure care that adapts instead of escalating too early.
Technical Specification
System Type: Hybrid mattress with paired air cells and profiled foam inserts, supported by a rebound foam layer for airflow and natural movement.
Clinical Use:
- Prevention and management of pressure injuries as a standalone mattress.
- With the EP10AU pump, delivers alternating pressure therapy suitable for treatment of pressure injuries up to stage 4.
- Mattress Sizes: Single: 88 cm × 200 cm × 19.5 cm · King Single: 107 cm × 200 cm × 19.5 cm
- Firmness & Profile: Medium-firm, 19.5 cm profile
- Safe Working Load: Up to 230 kg without pump · Up to 250 kg with pump
Cover Technology
- Pure Guard Cover — Four-way stretch, vapour-permeable, antimicrobial surface that reduces shear and supports skin protection.
- Hydro Lock Barrier — Welded seams and a liquid-resistant zip flap prevent fluid ingress and protect the mattress core.
Pressure Relief Features
- Anti-shear surface reduces tissue strain
- Heel relief zone offloads pressure on vulnerable areas.
- Reinforced side walls for stability
- Stability Core base with anti-slip underside for secure placement
- Mattress: 5 years warranty
- Pump: 10 years conditional warranty*
*Click here: Check Warranty Terms
Know Your Mattress
|
|
|
|
|
|
|---|---|---|---|---|
| Features |
E400
|
E500
|
E600
|
E700
|
| System Type | Hybrid (air-foam) | Alternating Hybrid (air-foam) | Alternating Air (1-in-2 cells) | Advanced Alternating Air (1-in-4 cells) |
| Use | Clinical | Clinical Pain Relief, Rehab, Palliative Care | High-risk Pressure, Surgical, Frailty | Complex Rehab, Spinal, ICU |
| Pressure Injury Stage | Stage 1-2 w/o pump, Stage 3-4 with pump | Stage 4 | Stage 4 | Stage 4 |
| Safe Load | 230 KG w/o pump, 250 Kg with pump | 230 KG | 200 KG | 200 KG |
| Sizes (cms) | S: 88 × 200 × 19.5 · KS: 107 × 200 × 19.5 | S: 88 × 200 × 19.5 · KS: 107 × 200 × 19.5 | S: 90 × 200 × 20 · KS: 105 × 200 × 20 | S: 90 × 200 × 20 · KS: 105 × 200 × 20 |
| Heel Relief Slope | ✓ | ✓ | ✕ | ✓ |
| Heel Offload | ✓ | ✓ | ✓ | ✓ |
| Static Head Support | ✓ | ✓ | ✓ | ✓ |
| Elata Pump | EP10AU | EP20AU | EP10AU | EP20AU |
| Tiltsense™ | ✕ | ✓ | ✕ | ✓ |
| Up to 12 hr Battery Backup | ✕ | ✓ | ✕ | ✓ |
| CPR Valve | ✕ | ✕ | ✓ | ✓ |
| Cable Tidy | ✓ | ✓ | ✓ | ✓ |
| Profile Height | 19.5 CM | 19.5 CM | 20 CM | 20 CM |
Frequently Asked Questions
E400 is most appropriate for clients at moderate to high pressure risk who require more than foam support but may not yet need full alternating air therapy. It sits between clinical foam and advanced alternating systems, offering responsive pressure redistribution with the flexibility to step up if needed.
Yes. The E400 can be paired with the compatible Elata EP10AU pump to activate dynamic alternating therapy. This allows clinicians to escalate care without replacing the entire mattress, supporting evolving patient needs while protecting long-term investment.
E400 combines air cells with a supportive foam base, delivering stable comfort with responsive pressure redistribution. Unlike full alternating air systems, it maintains a more familiar sleep surface while offering the option to step into dynamic therapy. It provides balance, greater protection than foam alone, with less complexity than advanced alternating air systems.